DPA / DPAS

Combine Accuracy and Ease of Use

 

The DPA/DPAS are pre-pressurized, gel-filled, low-maintenance pH or redox

sensors for in-line measurements of industrial processes. Pre-pressurized reference electrolyte prevents influx of process medium and keeps the reference junction

clean. The silver-ion trap prevents reference junction fouling even in solutions containing sulfide. The DPAS delivers fast and precise measurements, even after repeated autoclaving or sterilization cycles at 130 °C266 °F).

The DPA/DPAS sensors are also available as a platinum redox (ORP) sensor for oxidation-reduction measurements.

 



 

 

 

 

 

 

 

 


 


pH range                          0 14 pH                              0 12 pH

Temperature                       0 to 100 °C (32 to 212 °F       0 to 130 °C (32 to 266 °F

Pressure                          0 to 2.5 barg (0 to 36 psig)     0 to 2.5 barg (0 to 36 psig) Plug head    S8 screw cap,   K8S screw cap,

Pg 13.5                               Pg 13.5

(for AS9 connector)                     (for AK9 connector)

Reference system                Argenthal with silver-ion trap     Argenthal with silver-ion trap

Type of junction                  Ceramic                                 Ceramic

Reference electrolyte             Pre-pressurized gel                     Pre-pressurized gel

Lengths                           120 mm, 225 mm, 425 mm   120 mm, 200 mm, 225 mm,

325 mm, 425 mm, 600 mm

Shaft diameter                    12 mm                                 12 mm

Temperature sensor               None                                     None

Sterilizable                        No                                       Yes

Autoclavable                      No                                       Yes

Glass membrane                 High alkali quality glass               pH sensitive quality glass

Certificates                        Quality certificate                       Quality certificate

 

 

Feature Overview

Gel electrolyte does not require refilling, reduces maintenance

Silver-ion trap prevents poisoning by sulfide-bearing substances

Redox version available

Option (DPAS only): watertight VarioPin connector (IP 68) for easy connection and excellent signal transmission


 


 

 

 


Typical Applications (DPA)

Industrial processing

Reaction tanks

Mixing vessels

 

Typical Applications (DPAS)

Benchtop fermentors and bio-reactors

Hygienic processes requiring autoclaving or SIP


 


 

Ordering Information

DPA Electrodes            Sensor Type

Electrode Connection

Length

Order Number

pH Electrodes

 

 

 

HA-405-DPA-SC-S8           HA glass

S8

120 mm

10 405 4476IG

HA-405-DPA-SC-S8           HA glass

S8

225 mm

10 405 4477IG

HA-405-DPA-SC-S8           HA glass

S8

425 mm

10 405 4478IG

Redox Electrodes

 

 

 

Pt 4805-DPA-SC-S8           Pt

S8

120 mm

10 505 3339IG

Pt 4805-DPA-SC-S8           Pt

S8

225 mm

10 505 3338IG

Pt 4805-DPA-SC-S8           Pt

S8

425 mm

10 505 3340IG

DPAS Electrodes          Sensor Type

Electrode Connection

Length

Order Number

pH Electrodes

 

 

 

405-DPAS-SC-K8S            A41 glass

K8S

120 mm

10 405 4479

405-DPAS-SC-K8S            A41 glass

K8S

200 mm

10 405 4480

405-DPAS-SC-K8S            A41 glass

K8S

225 mm

10 405 4481

405-DPAS-SC-K8S            A41 glass

K8S

250 mm

41 405 4485

405-DPAS-SC-K8S            A41 glass

K8S

325 mm

10 405 4482

405-DPAS-SC-K8S            A41 glass

K8S

425 mm

10 405 4483

405-DPAS-SC-K8S            A41 glass

K8S

600 mm

11 405 3126

Redox Electrodes

 

 

 

Pt 4805-DPAS-SC-K8S   Pt

K8S

120 mm

10 505 3334

Pt 4805-DPAS-SC-K8S   Pt

K8S

200 mm

10 505 3335

Pt 4805-DPAS-SC-K8S   Pt

K8S

225 mm

10 505 3336

Pt 4805-DPAS-SC-K8S   Pt

K8S

325 mm

10 505 3337

For pH buffers, refer to “pH and Redox Accessories” section.

For cables, cable lengths and for terminating connectors, refer to “Cables” section on pages 152 155.

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7